![]() Your splines should be a fillet root, side fit type, because the interface is designed to be radially located by a shoulder on the pump flange, and not by the spline itself. ANSI B92.1 splines are designed with tooth thickness and space width tolerances to allow a fit between mating parts with different classes. ANSI B92.1 will give you the dimensions you need for a mating spline. ![]() The AA size shaft is a 9T, 20/40 DP spline, and the A size shaft is a 9T, 16/32 DP spline. The pump shafts with a 9T, 30deg PA involute male spline are SAE A or AA. ![]() Commercial hydraulic pumps (in the US) generally have standardized flange/shaft configurations.